Year : 2020  |  Volume : 24  |  Issue : 4  |  Page : 369-374  

Effectiveness of fluoride varnish, diode laser, and their combination in treatment of dentin hypersensitivity: A randomized split-mouth clinical trial


1 Department of Periodontics, Goa Dental College and Hospital, Bambolim, Goa, India
2 Department of Oral Surgery, Saraswati Dental College, Lucknow, Uttar Pradesh, India

Date of Submission23-Sep-2019
Date of Decision13-Dec-2019
Date of Acceptance25-Dec-2019
Date of Web Publication05-Jun-2020

Correspondence Address:
Akanksha Jain
Department of Periodontics, Goa Dental College and Hospital, Opposite Goa Medical College and Hospital, Rajiv Gandhi Complex, Bambolim - 403 202, Goa
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jisp.jisp_494_19

Rights and Permissions
   Abstract 


Background: Dentin hypersensitivity is a common dental problem with no permanent cure and predictable prognosis. Aim: The aim of this study was to evaluate the effectiveness of fluoride varnish (sodium fluoride [NaF]), diode laser, and the combination of NaF and diode laser in the treatment of dentin hypersensitivity. Settings and Design: This was a randomized split-mouth clinical trial. Materials and Methods: Sixty patients aged 20–60 years suffering from dentin hypersensitivity to air-blast, cold, and tactile stimulation corresponding to 4 cm and above on the Visual Analog Scale (VAS) in three quadrants with at least two hypersensitive teeth per quadrant were selected. Hypersensitive teeth were allotted to Group 1 – 5% NaF varnish application alone, Group 2 – 810-nm gallium–aluminum–arsenide laser (GaAlAs) diode laser (0.5 W) irradiation alone, and Group 3 – NaF varnish application, followed by diode laser irradiation. VAS score was recorded at baseline, 1 week, 2 weeks, 1 month, 3 months, and 6 months. Results: A statistically significant reduction in dentin hypersensitivity was observed in all the three groups, from the baseline to the 1st-, 3rd-, and 6th-month follow-ups (P < 0.05). Group 2 and Group 3 demonstrated a significantly higher reduction (P < 0.05) in dentin hypersensitivity for all the stimuli as opposed to Group 1 at all follow-up intervals. However, no statistically significant difference (P > 0.05) was present between Group 2 and Group 3 at all follow-ups. Conclusion: Diode laser is significantly more effective than fluoride varnish alone in the treatment of dentin hypersensitivity over a period of 6 months.

Keywords: Dentin sensitivity, fluoride, laser, varnish


How to cite this article:
Jain A, Rao J, Pal N, Singh A. Effectiveness of fluoride varnish, diode laser, and their combination in treatment of dentin hypersensitivity: A randomized split-mouth clinical trial. J Indian Soc Periodontol 2020;24:369-74

How to cite this URL:
Jain A, Rao J, Pal N, Singh A. Effectiveness of fluoride varnish, diode laser, and their combination in treatment of dentin hypersensitivity: A randomized split-mouth clinical trial. J Indian Soc Periodontol [serial online] 2020 [cited 2020 Aug 4];24:369-74. Available from: http://www.jisponline.com/text.asp?2020/24/4/369/286114




   Introduction Top


Dentin hypersensitivity is a common clinical problem encountered in dentistry.[1] Sensory stimuli do not yield any response in healthy teeth but lead to exaggerated response in hypersensitive teeth.[2] An international workshop defines this condition as: “Dentin hypersensitivity is characterized by short, sharp pain arising from exposed dentin in response to stimuli, typically thermal, evaporative, tactile, osmotic or chemical and which cannot be ascribed to any other dental defect or pathology.”[3]

Enamel can be worn off by attrition, abrasive toothbrushing, and erosion from acidic diet and parafunctional habits. The root surfaces of teeth can be exposed by gingival recession and periodontal disease.[4] Dentin abrades 25 times, whereas cementum abrades 35 times more easily than enamel.[5] The most accepted theory for hypersensitivity is the hydrodynamic theory. This theory attributes the movement of dentinal fluid in either direction within the dentinal tubules on application of an external stimulus.[6] This excites the pulp's mechanoreceptors in turn and results in hypersensitivity, perceived as pain by the patient.[7]

Dentin hypersensitivity can range from slight discomfort to extreme pain depending on the individual's pain perception and tolerance. A variety of desensitizing agents have been recommended to reduce dentin hypersensitivity, which include nerve-desensitizing agents, protein-precipitating agents, dentin adhesive sealers, agents plugging dentinal tubules, and homeopathic agents.[8]

Sodium fluoride (NaF) was first proposed as a desensitizing agent by Lukomsky.[9] Fluoride varnish was also favored by Porto et al. due to its ease of application and immediate action.[10] In 1985, lasers were introduced as a potential desensitizing tool.[11] The working parameters such as wavelength and the power density of the laser and the optical properties of the target tissue can lead to different tissue reactions.[12] Kimura et al. reported an effectiveness varying from 5.2% to 100% depending on the laser parameters being used.[13] The combination of lasers with chemical substances such as fluorides presents as an additional therapeutic option. In various clinical studies, the effectiveness of more than 20% has been found over the laser treatment alone.[14]

Dentin hypersensitivity has been the topic of research since the past decade. Many treatment modalities that obliterate the dentinal tubules are available; however, till date, no consensus regarding the most efficient method for treating dentin hypersensitivity has been published. Effective therapeutic options that provide long-lasting relief with a predictable prognosis are being explored even today. Thus, this study aimed to evaluate the effectiveness of the 810-nm diode laser alone and in combination with 5% NaF varnish in the treatment of dentin hypersensitivity.


   Materials and Methods Top


In this split-mouth, double-blind, randomized control trial, sixty systemically healthy controls aged 20–60 years visiting the outpatient department of periodontics and fulfilling the inclusion criteria were selected for the study. Inclusion criteria:

  1. The presence of a minimum of two teeth, hypersensitive to tactile, cold, or air stimulation corresponding to 4 cm and above on the Visual Analog Scale (VAS) in three quadrants
  2. Willingness to provide written informed consent for being included in the study.


Patients who had received any professional treatment with desensitizing agents during the past 6 months; patients with a history of antibiotics, anti-inflammatory drug, or immunosuppressive drug therapy in the past 6 months; patients who underwent periodontal treatment in the past 6 months; patients with history of any systemic disease or allergy to fluorides; pregnant or lactating women; smokers; and chronic alcoholics were excluded from the study. The teeth having carious lesions, extensive restorations, endodontic treatment on the selected teeth, teeth diagnosed to have cracked tooth syndrome, vertical fracture, and pulpitis were also excluded from the study.

The study was approved by the institution's ethical committee and review board and was conducted in accordance with the Helsinki Declaration as revised in 2013.

In each patient, hypersensitive teeth in three different quadrants were randomly assigned to one of the three treatment groups by a lottery method. In Group 1, NaF varnish application was done, in Group 2, diode laser application, and in Group 3, NaF varnish, followed by diode laser application, was done. A total of 626 teeth were evaluated for dentin hypersensitivity, of which 207 teeth were treated with NaF varnish, 207 teeth were treated with diode laser, and 212 teeth were treated with the combination of NaF and diode laser.

Clinical parameter used for recording hypersensitivity score

VAS score for each stimulus was recorded before each treatment session (at baseline, 1 week, and 2 weeks), followed by VAS score recording at 1 month, 3 months, and 6 months. The following stimuli were used for the assessment of dentin hypersensitivity with a 5-min gap between each stimulus.

Air-blast stimulus

Three-way syringe attached to the dental chair was used, kept at a distance of 0.5 cm, and perpendicular to the tooth surface for 1 s per tooth at room temperature.

Cold stimulus

A precooled 2-ml disposable syringe was filled with freshly melted ice-cold water. After isolating the specific tooth, 0.5 ml of the water was slowly expelled from the syringe on the tooth surface.

Tactile stimulus

The University of North Carolina-15 probe tip was moved back and forth in contact on the buccal tooth surface.

Adjacent teeth were covered with the operator's fingers and or cotton rolls while dentin stimulation. A single operator evaluated all teeth for hypersensitivity while other operators performed all the treatments assigned.

In each patient, periodontal therapy consisting of full-mouth scaling and root planing using hand instruments and ultrasonic scaler, followed by oral hygiene instructions, was given. Dentin hypersensitivity was assessed and recorded for the three stimuli (air blast, cold, and tactile) before initiating any hypersensitivity treatment. After recording the baseline dentin hypersensitivity scores, hypersensitive teeth in different quadrants were assigned to one of the three treatment groups:

Group 1 (sodium fluoride varnish application)

Hypersensitive teeth in the selected quadrant were treated by application of NaF varnish (Fluoritop SR Varnish containing 50-mg NaF equivalent to 22,600 ppm of fluoride, ICPA, India) for 2 min using a disposable applicator tip [Figure 1].
Figure 1: Fluoride varnish application using applicator tip

Click here to view


Group 2 (diode laser application)

Hypersensitive teeth in the selected quadrant were irradiated using GaAlAs diode laser: 810 nm (Picasso, AMD lasers, Dentsply International Co., United States), power 0.5 W continuous emission form. Each tooth was irradiated for 2 min in noncontact mode with the laser beam directed perpendicular to the buccal surface of the tooth [Figure 2].
Figure 2: Diode laser application

Click here to view


Group 3 (sodium fluoride varnish + diode laser application)

Hypersensitive teeth in the selected quadrant were treated by application of fluoride varnish for 2 min, followed by irradiation treatment using 810-nm GaAlAs diode laser, power 0.5 W continuous emission form. Each tooth was irradiated for 2 min in noncontact mode with the laser beam directed perpendicular to the buccal surface of the tooth [Figure 3]. All patients were instructed not to eat for 1 h following each session and to resume toothbrushing after 12 h.
Figure 3: Fluoride varnish application, followed by diode laser application

Click here to view


Statistical analysis was performed using the statistical software SPSS version 20.0 (SPSS Inc., Chicago, IL, USA) by a third operator. Descriptive statistics such as median, interquartile range, minimum, and maximum were calculated for all the variables. Statistical significance was set at a 5% probability level. The Friedman test was used to assess whether there is a significant difference in the dentin hypersensitivity using three different stimuli at different time intervals. Post hoc Wilcoxon signed-rank test, followed by Bonferroni adjustment, was used for pairwise comparisons on the different combinations of related groups. The Kruskal–Wallis test was used to compare the three treatments at each time interval for each stimulus. Post hoc Mann–Whitney U-test with Bonferroni adjustment was used for pairwise comparisons.


   Results Top


Sixty patients (33 females and 27 males) with a mean age of 36 years were evaluated for 6 months. In the present study, there were no statistically significant differences in the dentin hypersensitivity score between the three treatment groups with regard to air-blast, cold, and tactile stimuli at baseline examination (P ≥ 0.05) that ensured that randomization of the treatment groups was successful [Table 1]. On intragroup comparison, all the three treatment modalities (Group 1, Group 2, and Group 3) lead to a statistically significant reduction (P ≤ 0.05) in dentin hypersensitivity from the baseline to the 1st, 3rd, and 6th months for all the three stimuli – air blast, cold, and tactile [Table 2].
Table 1: Descriptive statistics depicting dentin hypersensitivity score in the three groups

Click here to view
Table 2: Intragroup comparison of dentin hypersensitivity using Wilcoxon signed-rank test from baseline to 1-, 3-, and 6-month intervals

Click here to view


On intergroup comparison, there was a significantly higher reduction (P < 0.05) in dentin hypersensitivity in Group 2 and Group 3 for all the three stimuli – air blast, cold, and tactile [Table 3] when compared to Group 1 at the 1st-, 3rd-, and 6th-month follow-up intervals. Group 3 leads to higher reduction in dentin hypersensitivity using air-blast, cold, and tactile stimuli when compared to Group 2 after dentin stimulation using air-blast, cold, and tactile stimuli; however, the difference between the two treatment groups was not statistically significant at the follow-up intervals (P > 0.05) [Table 3].
Table 3: Intergroup comparison of dentin hypersensitivity using Mann–Whitney U-test at follow-up intervals

Click here to view



   Discussion Top


The prevalence of dentin hypersensitivity varies between 3% and 57% in the general population. Root instrumentation during periodontal therapy may lead to cementum removal which explains the higher frequency of dentin hypersensitivity (60%–98%) in periodontitis patients.[15] Split-mouth study design was used in the present study to facilitate the comparison of the three treatment methods under similar and standardized conditions. The patients who underwent treatment with desensitizing agents or periodontal treatment during the past 6 months were excluded to prevent any manipulation of the results due to the past desensitizing procedure.

According to the results obtained, on intragroup comparison, a statistically significant reduction in hypersensitivity was observed from the baseline to the 1st, 3rd, and 6th months for all the stimuli in the three groups. The relief in hypersensitivity in Group 1 can be explained by the prolonged contact time of fluoride with the tooth surface due to the sticky consistency of varnish. The varnish dries rapidly leaving behind a thin, transparent coating.[9] There is a deposition of calcium fluoride (CaF2) crystals on the tooth surface which blocks the patent dentinal tubules.[16] The relief in hypersensitivity in Group 2 and Group 3 can be explained by the secondary dentin formation through stimulation of odontoblasts after laser irradiation.[17] This occludes the dentinal tubules and reduces the dentinal fluid movement. Diode laser also causes depolarization of the nerve endings present at the dentin/pulp interface, thereby increasing the pain threshold.[2]

In the present study, there was a significantly higher reduction in dentin hypersensitivity in Group 2 and Group 3 for all the three stimuli when compared to Group 1 at all follow-up intervals. The action of the varnish in occluding the dentinal tubules is comparatively short-lived due to small crystal size of CaF2(about 0.05 μm) that precipitates formed on the outer dentin surface and its tendency to be removed during toothbrushing. The precipitate may be removed over time due to the presence of saliva or factors such as acid from dental biofilm, food, and acid beverages.[18] This might lead to reopening of the patent dentinal tubules and thus triggering hypersensitivity. However, the relief after the use of low-level diode laser is due to depressed nerve transmission within the dental pulp along with the internal obliteration of dentinal tubules. The secondary dentin formed is not affected by mechanical forces. There is no reopening of the patent dentinal tubules which helps in maintaining the desensitizing effect.

Similar results were obtained in previous studies, according to which diode laser whether used alone or combined with fluoride varnish was significantly more effective than fluoride varnish alone (P < 0.05).[19],[20],[21],[22],[23] However, the present results were in contrast to the results observed by Corona et al. and Dantas et al., who reported no significant difference between diode laser and fluoride varnish in reducing hypersensitivity (P > 0.05).

In the present study, Group 3 reported a higher reduction in dentin hypersensitivity using air-blast, cold, and tactile stimuli when compared to Group 2; however, no significant difference was observed between the two groups at any follow-up interval. Similar findings were observed by Tailor et al. who evaluated the efficacy 808 ± 10 nm diode laser with topical fluoride (6% NaF and 6% CaF2) in the reduction of dentin hypersensitivity.

According to the results of some studies, lasers work in harmony with desensitizing agents.[24],[25],[26],[27] They help in prolonging the contact of the desensitizer agent on the tooth surface. However, a direct comparison with the results of the present study cannot be made due to the differences in the fluoride treatment and the emission wavelength of the diode laser used.

Regardless of the methodology employed, different patients have different pain threshold which might obscure the results of the study and reduce the reliability of the results obtained.[28] This was a major limitation of the present study. Although the adjacent teeth were isolated using cotton rolls and operator's fingers, the use of rubber dam may have resulted in more precise measurements. Oral prophylaxis was not repeated after baseline evaluation of dentin hypersensitivity till the end of 6 months. The presence of supragingival deposits could have altered the dentin hypersensitivity. Although a single examiner performed dentin stimulation using air-blast, cold, and tactile stimuli, variations in the pressure of the tactile stimulus, pressure of the air from the three-way dental syringe for air-blast stimulus, and temperature variation of freshly melted ice-cold water could not be avoided and could have affected the results. Other limitations included a lack of placebo-controlled design.


   Conclusion Top


It can be concluded that both fluoride varnish and diode laser are effective in treating dentin hypersensitivity. However, diode laser used alone and in combination with fluoride varnish is significantly more effective than fluoride varnish alone in the treatment of dentin hypersensitivity.

Acknowledgement

We would like to thank Mrs. Pallavi Nachinolkar, Department of Public Health Dentistry, Goa Dental College and Hospital, Bambolim, Goa, for helping us in the statistical analysis.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
   References Top

1.
Addy M. Dentine hypersensitivity: Definition, prevalence, distribution and etiology. In: Addy M, Embery G, Edgar WM, Orchardson R, editors. Tooth Wear and Sensitivity: Clinical Advances in Restorative Dentistry. London: Martin Dunitz; 2000. p. 239-48.  Back to cited text no. 1
    
2.
Orchardson R, Gangarosa LP Sr., Holland GR, Pashley DH, Trowbridge HO, Ashley FP, et al. Dentine hypersensitivity-into the 21st century. Arch Oral Biol 1994;39 Suppl: 113S-119S.  Back to cited text no. 2
    
3.
Holland GR, Narhi MN, Addy M, Gangarosa L, Orchardson R. Guidelines for the design and conduct of clinical trials on dentine hypersensitivity. J Clin Periodontol 1997;24:808-13.  Back to cited text no. 3
    
4.
Corona SA, Nascimento TN, Catirse AB, Lizarelli RF, Dinelli W, Palma-Dibb RG. Clinical evaluation of low-level laser therapy and fluoride varnish for treating cervical dentinal hypersensitivity. J Oral Rehabil 2003;30:1183-9.  Back to cited text no. 4
    
5.
Kim JL, Karastathis D. Dentinal hypersensitivity management. In: Darby ML, Walsh MM. Dental Hygiene Theory and Practice. 3rd ed. St. Louis, MO: Saunders-Elsevier; 2010. p. 726-35.  Back to cited text no. 5
    
6.
Wichgers TG, Emert RL. Dentin hypersensitivity. Gen Dent 1996;44:225-30.  Back to cited text no. 6
    
7.
Brännström M, Aström A. The hydrodynamics of the dentine; its possible relationship to dentinal pain. Int Dent J 1972;22:219-27.  Back to cited text no. 7
    
8.
Mittal R, Singla MG, Sood A, Dua A, Sodhi PS. Clinical evaluation of middle power output 810 nm GaAlAs Diode Laser for treating severe dentin hypersensitivity: A randomised clinical trial. Int J Laser Dent 2014;4:20-5.  Back to cited text no. 8
    
9.
Kumar NG, Mehta DS. Short-term assessment of the Nd:YAG laser with and without sodium fluoride varnish in the treatment of dentin hypersensitivity – A clinical and scanning electron microscopy study. J Periodontol 2005;76:1140-7.  Back to cited text no. 9
    
10.
Porto IC, Andrade AK, Montes MA. Diagnosis and treatment of dentinal hypersensitivity. J Oral Sci 2009;51:323-32.  Back to cited text no. 10
    
11.
West NX, Lussi A, Seong J, Hellwig E. Dentin hypersensitivity: Pain mechanisms and aetiology of exposed cervical dentin. Clin Oral Investig 2013;17 Suppl 1:S9-19.  Back to cited text no. 11
    
12.
Ladalardo TC, Pinheiro A, Campos RA, Brugnera Júnior A, Zanin F, Albernaz PL, et al. Laser therapy in the treatment of dentine hypersensitivity. Braz Dent J 2004;15:144-50.  Back to cited text no. 12
    
13.
Kimura Y, Wilder-Smith P, Yonaga K, Matsumoto K. Treatment of dentine hypersensitivity by lasers: A review. J Clin Periodontol 2000;27:715-21.  Back to cited text no. 13
    
14.
Asnaashari M, Moeini M. Effectiveness of lasers in the treatment of dentin hypersensitivity. J Lasers Med Sci 2013;4:1-7.  Back to cited text no. 14
    
15.
von Troil B, Needleman I, Sanz M. A systematic review of the prevalence of root sensitivity following periodontal therapy. J Clin Periodontol 2002;29 Suppl 3:173-7.  Back to cited text no. 15
    
16.
Osmari D, de Oliveira Ferreira AC, de Carlo Bello M, Henrique Susin A, Cecília Correa Aranha A, Marquezan M, et al. Micromorphological evaluation of dentin treated with different desensitizing agents. J Lasers Med Sci 2013;4:140-6.  Back to cited text no. 16
    
17.
Walsh LJ. The current status of low level laser therapy in dentistry. Part 2. Hard tissue applications. Aust Dent J 1997;42:302-6.  Back to cited text no. 17
    
18.
Dantas EM, Amorim FK, Nóbrega FJ, Dantas PM, Vasconcelos RG, Queiroz LM. Clinical efficacy of fluoride varnish and low-level laser radiation in treating dentin hypersensitivity. Braz Dent J 2016;27:79-82.  Back to cited text no. 18
    
19.
Yilmaz HG, Kurtulmus-Yilmaz S, Cengiz E. Long-term effect of diode laser irradiation compared to sodium fluoride varnish in the treatment of dentine hypersensitivity in periodontal maintenance patients: A randomized controlled clinical study. Photomed Laser Surg 2011;29:721-5.  Back to cited text no. 19
    
20.
Jain PR, Naik GD, Uppor SA, Kamath DG. Diodelaser and fluoride varnish in the management of dentin hypersensitivity. J Interdiscip Dent 2015;5:71-4.  Back to cited text no. 20
    
21.
Tailor A, Shenoy N, Thomas B. To compare and evaluate the efficacy of bifluorid 12, diode laser and their combined effect in treatment of dentinal hypersensitivity – A clinical study. Nitte Univ J Health Sci 2014;4:54-8.  Back to cited text no. 21
    
22.
Pesevska S, Nakova M, Ivanovski K, Angelov N, Kesic L, Obradovic R, et al. Dentinal hypersensitivity following scaling and root planing: Comparison of low-level laser and topical fluoride treatment. Lasers Med Sci 2010;25:647-50.  Back to cited text no. 22
    
23.
Todea CD, Miron MI, Filip LM, Petre A. The efficiency of laser in the hypersensitivity therapy in cervical erosion. Timisoara Med J 2003;2:176-80.  Back to cited text no. 23
    
24.
Suri I, Singh P, Shakir QJ, Shetty A, Bapat R, Thakur R. A comparative evaluation to assess the efficacy of 5% sodium fluoride varnish and diode laser and their combined application in the treatment of dentin hypersensitivity. J Indian Soc Periodontol 2016;20:307-14.  Back to cited text no. 24
[PUBMED]  [Full text]  
25.
Joshi I, Dodwad V, Tevatia S, Singla R. Comparative evaluation of the efficacy of diode laser as an adjunct to stannous fluoride in the management of dentinal hypersensitivity: A clinical study. Res Rev J Dent Sci 2016;4:84-9.  Back to cited text no. 25
    
26.
Ranjan R, Yadwad KJ, Patil SR, Mahantesha S, Rahman AA, Bhatia VB. Efficacy of 980 nm diode laser as an adjunct to Snf2 in the management of dentinal hypersensitivity: A controlled, prospective clinical study. J Dent Lasers 2013;7:66-71.  Back to cited text no. 26
  [Full text]  
27.
Liu HC, Lan WH. The combined effectiveness of the semiconductor laser with duraphat in the treatment of dentin hypersensitivity. J Clin Laser Med Surg 1994;12:315-19.  Back to cited text no. 27
    
28.
Canadian Advisory Board on Dentin Hypersensitivity. Consensus-based recommendations for the diagnosis and management of dentin hypersensitivity. J Can Dent Assoc 2003;69:221-6.  Back to cited text no. 28
    


    Figures

  [Figure 1], [Figure 2], [Figure 3]
 
 
    Tables

  [Table 1], [Table 2], [Table 3]



 

Top
   
 
  Search
 
  
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    Abstract
   Introduction
    Materials and Me...
   Results
   Discussion
   Conclusion
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed102    
    Printed3    
    Emailed0    
    PDF Downloaded44    
    Comments [Add]    

Recommend this journal